Modern byggnad för nybyggen

    For New Builds

    Easy to design into new builds

    To effortlessly create the most energy-efficient property possible. A few things to keep in mind for new builds. 3E should be installed up to the last 30–40 metres before the draw-off point for optimum comfort. Up to 12 storeys, no hot water recirculation is needed up through the floors; a short recirculation loop on the ground floor with 3E in the vertical shafts is sufficient. If the building has more than 12 storeys and you want to maintain optimum comfort, we recommend running hot water recirculation in one (1) shaft, then routing 3E out onto the floors. That way, only one shaft requires hot water recirculation, and none is needed out on the floors.

    Energirenovering med 3E

    For Energy Retrofit

    Use existing pipes – Residents do not need to move out

    Postpone pipe replacement with 3E Riser. Pipe replacements are most often carried out because the hot water recirculation pipes have worn out. Domestic hot water pipes and drains do not wear out in the same way and usually last significantly longer, but typically everything is replaced at the same time. With 3E Riser, we can instead cap the recirculation pipes and install 3E on the existing hot water pipes. This allows pipe replacement to be postponed for many years. 3E Energy Renovation cuts domestic hot water energy consumption by 40% without major disruption. Installation takes just a few hours per riser, and residents can stay in their homes. You install a product instead of launching a project.

    Read more about 3E Riser & Energy Retrofit
    Innergård för stambyte

    For Pipe Replacement

    Use the same shaft

    With 3E, pipes do not need insulation and take up so little space that in most cases you can cap the existing pipes, leave them in place, and reuse the same shaft.

    Different ways to install 3E

    1. Series
    1. Series
    White pipe = Empty pipe
    Red pipe = Filled pipe
    Blue pipe = Cold water
    1. Series

    3E is routed to the kitchen, with a branch to the bathroom. The entire line from the 3E Flow Control to the 3E Damping Chamber empties when the tap is turned off, excluding the branches after the 3E Check Valve. In this example, the lower flat shows a filled pipe where water is in use, and the upper flat shows an empty pipe where no water is being used.

    In these examples, 3E is only installed on hot water; cold water is installed conventionally.

    2. Riser / Shaft
    3. Standard